CC450-AE ABSOLUTE ENCODER


GENERAL

The CC450-AE Absolute Encoder is used as a position feedback device where absolute measurement is required. It is a rugged electrical device and should be transformer coupled to the control system to avoid any induced noise via control common.

APPLICATION

The 450-AE Absolute Encoder is designed for use as a positioning feedback device in mill duty environments. Among its features are:

  1. Absolute Measurement - Retains exact position throughout a power shutdown
  2. Long-line Transmission capability
  3. Very high degree of noise rejection.

ELECTRICAL SPECIFICATIONS

Code 10 Bit Gray Code
10 Bit Natural Binary
Supply Voltage 12-15 VDC
Supply Current 200mA Max
Output Voltage (TTL) 12 VDC
Operating Temperature to 70° C

MECHANICAL SPECIFICATIONS
Housing NEMA 13
Material-6061 Anodized Aluminum
Seal - O - Ring
Fastners 303 Stainless Steel 

Shaft Size

0.4998" (+.0000, -.0005)
316 Stainless Steel
 
1/8" Keyway
Shaft Seal Teflon Graphite 
Moment of Inertia

1550g/ cm2

Bearing Life 2 x 108 Revs at rated shaft loading

Shaft Torque

0.5 to 1.0 oz - in w/o seal
1.0 to 2.0 oz - in w/ seal
Shaft Runout 0.0005 T.I.R.  
Speed 700RPM, with shaft seal before gearing 
Weight 12 lb.

ORDERING INFORMATION

How to build your CC450AE Model Number

EXAMPLE: CC450AE-10G-200:1-FM-C
SPECIFICATIONS
450AE   10G   200:1   FM   C
MODEL   1   2   3   4

MODEL = CC450AE   =   BASIC (Mill Duty) DESIGN
1 = ABSOLUTE ENCODER CONFIGURATION
_____10G 10 bit Gray Code
_____10N 10 bit Natural Binary
2 = GEAR RATIO
Note: All gear trains are of anti-backlash design

Gear-Down
Available from 1:1 to 100:1 to and including 1600:1
Also avail. are ratios between numbers, for example: 2.5:1

X:X = # of input turns to encoder turns. Ex.: 10:1 means for every ten turns of the machine shaft the AE (10 bits) will turn once

Gear-Up
Available from 1:1 to 1:100
Also available are ratios between numbers, for example: 1:1.5

 

3 = MOUNTING
_____FM = Foot Mount
_____56C = NEMA 56C Flange
_____MM = Motor Mount (mounts directly to DC Kinematic Motor)
_____DS = Base Plate to replace DS3820
_____S = Base Plate to replace Selsyn
_____46FM = BC46 & BC42 Foot Mounts and NEMA 56C Face Mount (MM)
_____56FM = CC56FM Foot Mount
_____FC = Motor Mount - Direct Mounting to 8" dia motor pilot with (4) 1/2-13 mounting holes on a 7.250"B.C.,includes coupling kit
_____45P = CC45P Flange Mount
_____45C = CC45C Flange Mount
Also available, various Adapter Plates for interfacing with existing devices,  for example: Selsyns and Limit Switches

4 = OUTPUT TERMINATION

_____MS = MS Connector, with mate
_____C = Conduit, 1/2" NPT tapped hole

 

 