APPLICATION The CC1500 linear transducer was originally designed for steel mill screwdown position control which requires a high degree of reliability in a hostile environment including heat, liquids and dirt. Other applications include coil cars, side guide positioning, down coilers, and continuous casting position control.
|
Linearity |
+ 0.01% of full scale * |
Resolution |
- 2 microns (0.00008 inch) at maximum of 10,000 measurements per second standard |
Repeatability |
- +0.001% of full scale or +0.002mm (0.0001 inches), whichever is greater |
Non-Linearity Uncorrected |
- <+0.02% of full scale or +0.002 inches, whichever is greater |
Hysteresis |
- <0.004mm (0.00015 inches) |
Operating Temperature |
- -40 to 85oC (-40 to 185oF) |
Outputs |
- Voltage (Range: 0 to +10VDC, reverse acting) Current (4 to 20mA grounded, reverse acting) (0 to 20mA grounded, reverse acting) Dual outputs of a common type: position and velocity or two positions |
Digital |
- SSI (Serial Synchronous Interface), CANbus |
Analog Adjustability |
- 100% adjustment of zero and span points |
Stroke Lengths |
- 25 to 7600mm (1 to 300 inches) |
Operating Voltage |
- +24VDC (+15%, -10%) |
* Linearization Data supplied for improved linearity. |
PRODUCT DIMENSIONS
Dimensions = Inches (mm)
ORDERING INFORMATION
Example: |
CC1500L |
1 |
G |
4 |
L |
A |
B |
C |
D |
A) Data Length
_____1 = 25 Bits
_____2 = 24 Bits
B) Output Format
_____B = Binary
_____G = Gray Code
C) Resolution
_____1 = 0.0002 in. ( 0.005 mm )
_____2 = 0.0004 in. ( 0.01 mm )
_____3 = 0.002 in. ( 0.05 mm )
_____4 = 0.004 in. ( 0.1 mm )
_____5 = 0.0008 in. ( 0.02 mm )
_____6 = 0.00008 in. ( 0.002 mm )
D) Performance
_____S = Standard
_____L = Linearization Package